Klimatska komora s regulacijom vlažnostiBinder
MKF 115 E3.1 -40°C bis 180°C
Klimatska komora s regulacijom vlažnosti
Binder
MKF 115 E3.1 -40°C bis 180°C
Stanje
Rabljeno
Lokacija
Borken 

Pokaži slike
Prikaži kartu
Podaci o stroju
Cijena i lokacija
- Lokacija:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Nazovi
Detalji ponude
- ID broj oglasa:
- A20959057
- Referentni br.:
- 24976
- Zadnje ažurirano:
- dana 15.01.2026
Opis
Binder
Model MKF 115 E3.1
Binder climatic test chamber, model MKF 115 E3.1
Temperature range: -40 °C to +180 °C
Hjdpfsx Ux Ivsx Ad Tsng
Humidity range: 10% r.h. to 98% r.h.
Integrated 20 L water reservoir
4 volt-free relay contacts
APT.line™ pre-heating chamber technology
Programmable condensation protection for samples
Heated viewing window with LED interior lighting
Humidity control with capacitive humidity sensor and steam humidification
BINDER Multi Management Software APT-COM™ Basic Edition
Fault diagnosis system with visual and acoustic alarm
Intuitive touchscreen controller with time and real-time programming
Internal data logger, measured data can be read via USB in an open format
Port with silicone stopper 50 mm, left
Temperature selection limiter class 2 (DIN 12880) with visual alarm
4 castors (2 with locking brake)
PC interface: Ethernet
230 V socket on the right-side control panel
Adjustable ramp function
Integrated line recorder
Real-time clock
Door heating
Alarm notification in case of fresh water tank shortage
2 stainless steel shelves
Hose burst protection, incl. water supply and discharge up to 1 m height
Interior made of stainless steel
Cooling via compression refrigeration unit
TECHNICAL DATA:
Housing dimensions:
Width 1000 mm Height 1725 mm incl. feet / castors Depth 865 mm incl. triangle & / connectors
Internal dimensions:
Width 600 mm Height 480 mm Depth 400 mm
Dimensions:
Internal volume 115 liters
Net device weight (empty) 280 kg
Maximum total load 60 kg
Maximum load per shelf 30 kg
Performance data temperature:
Temperature range -40...180°C
Temporal temperature deviation 0.1...0.6 ± K
Spatial temperature deviation 0.1...1.3 ± K
Average heating rate according to IEC 60068-3-5 5.5 K/min
Average cooling rate according to IEC 60068-3-5 4.5 K/min
Max. heat compensation 2500 W
Performance data climate:
Temperature range 10...95°C
Humidity range 10...98% r.h.
Temporal temperature deviation depending on setpoint 0.1...1.3 ± K
Max. heat compensation 400 W
Electrical data:
Nominal voltage 400V 3N~ ±10% 50Hz
Nominal output 4.5 kW 7.5 A
Energy consumption at 25°C / 60% r.h. 1.25 kW
Fittings:
Number of inserts 4/4 std./max.
Condition: used
Scope of delivery: (See image)
(Subject to changes and errors in technical specifications. All information supplied without liability!)
For further questions, feel free to contact us by phone.
Oglas je automatski preveden i možda je došlo do nekih grešaka u prijevodu.
Model MKF 115 E3.1
Binder climatic test chamber, model MKF 115 E3.1
Temperature range: -40 °C to +180 °C
Hjdpfsx Ux Ivsx Ad Tsng
Humidity range: 10% r.h. to 98% r.h.
Integrated 20 L water reservoir
4 volt-free relay contacts
APT.line™ pre-heating chamber technology
Programmable condensation protection for samples
Heated viewing window with LED interior lighting
Humidity control with capacitive humidity sensor and steam humidification
BINDER Multi Management Software APT-COM™ Basic Edition
Fault diagnosis system with visual and acoustic alarm
Intuitive touchscreen controller with time and real-time programming
Internal data logger, measured data can be read via USB in an open format
Port with silicone stopper 50 mm, left
Temperature selection limiter class 2 (DIN 12880) with visual alarm
4 castors (2 with locking brake)
PC interface: Ethernet
230 V socket on the right-side control panel
Adjustable ramp function
Integrated line recorder
Real-time clock
Door heating
Alarm notification in case of fresh water tank shortage
2 stainless steel shelves
Hose burst protection, incl. water supply and discharge up to 1 m height
Interior made of stainless steel
Cooling via compression refrigeration unit
TECHNICAL DATA:
Housing dimensions:
Width 1000 mm Height 1725 mm incl. feet / castors Depth 865 mm incl. triangle & / connectors
Internal dimensions:
Width 600 mm Height 480 mm Depth 400 mm
Dimensions:
Internal volume 115 liters
Net device weight (empty) 280 kg
Maximum total load 60 kg
Maximum load per shelf 30 kg
Performance data temperature:
Temperature range -40...180°C
Temporal temperature deviation 0.1...0.6 ± K
Spatial temperature deviation 0.1...1.3 ± K
Average heating rate according to IEC 60068-3-5 5.5 K/min
Average cooling rate according to IEC 60068-3-5 4.5 K/min
Max. heat compensation 2500 W
Performance data climate:
Temperature range 10...95°C
Humidity range 10...98% r.h.
Temporal temperature deviation depending on setpoint 0.1...1.3 ± K
Max. heat compensation 400 W
Electrical data:
Nominal voltage 400V 3N~ ±10% 50Hz
Nominal output 4.5 kW 7.5 A
Energy consumption at 25°C / 60% r.h. 1.25 kW
Fittings:
Number of inserts 4/4 std./max.
Condition: used
Scope of delivery: (See image)
(Subject to changes and errors in technical specifications. All information supplied without liability!)
For further questions, feel free to contact us by phone.