GBS Prüfpuls rev3 Pulse Generator for Long-Term Insulation Testing
The Prüfpuls setup is designed for long-term insulation tests on test specimens with up to 6 nF capacitance.
Converter for High Voltage Test Transformer
· Internal sine wave generator: 50–200 Hz
· Pulse width modulation of the sine wave via full bridge: 16–24 kHz
· Converter voltage adjustable from 0–600 V, Imax = 2.6 A, maximum output 1.3 kW
· Pulse current limitation 110 A (cut-off threshold)
Pulse Transformer – Control
· Controlled via full bridge
· Full-bridge power supply adjustable 0–1000 V, max. 1.3 A
· Pulse current limitation 100 A (cut-off threshold)
· Pulse width adjustable 20–120 μs, nominal 94 μs
· 2 selectable series inductances: 150 μH, 300 μH to adjust pulse width/rise time to load capacitance and voltage
Nedpsu Egz Rofx Al Sjcu
· Pulse repetition frequency adjustable 0.1 – 2.5 kHz
· Polarity: selectable as positive, negative or alternating, depending on sine signal polarity
· Cosine-shaped pulse at transformer output
Pulse Transformer Cascade
· Output transformers in 5-stage cascaded circuit
· Total transformation ratio selectable via taps: 1:7.7, 1:10, or 1:15
· Maximum output voltage 15 kV with possible load capacitance of: * 6 nF with a pulse width of 73 μs at a repetition rate of 2.5 kHz * 10 nF with a pulse width of 103 μs at a repetition rate of 1.25 kHz
· 1:1000 parallel voltage divider
· Overvoltage limitation at approx. 20–23 kV via parallel spark gaps
· Thermistor for overtemperature detection in 1st transformer stage
· Ground-side current measuring socket 100 mV/A
Breakdown Detection, Testing
· If the maximum bridge currents for transformer control or the max. currents of the full-bridge power supplies are exceeded, high voltage is switched off
· The device features a resettable operating hours counter to determine test duration
Manufacturer price approx. €59,500
Financing through our bank is also possible.
komplett-konzept.leasingo.de
More new and used items can be found in our shop!
International shipping costs on request!
Oglas je automatski preveden. Moguće su pogreške u prijevodu.
The Prüfpuls setup is designed for long-term insulation tests on test specimens with up to 6 nF capacitance.
Converter for High Voltage Test Transformer
· Internal sine wave generator: 50–200 Hz
· Pulse width modulation of the sine wave via full bridge: 16–24 kHz
· Converter voltage adjustable from 0–600 V, Imax = 2.6 A, maximum output 1.3 kW
· Pulse current limitation 110 A (cut-off threshold)
Pulse Transformer – Control
· Controlled via full bridge
· Full-bridge power supply adjustable 0–1000 V, max. 1.3 A
· Pulse current limitation 100 A (cut-off threshold)
· Pulse width adjustable 20–120 μs, nominal 94 μs
· 2 selectable series inductances: 150 μH, 300 μH to adjust pulse width/rise time to load capacitance and voltage
Nedpsu Egz Rofx Al Sjcu
· Pulse repetition frequency adjustable 0.1 – 2.5 kHz
· Polarity: selectable as positive, negative or alternating, depending on sine signal polarity
· Cosine-shaped pulse at transformer output
Pulse Transformer Cascade
· Output transformers in 5-stage cascaded circuit
· Total transformation ratio selectable via taps: 1:7.7, 1:10, or 1:15
· Maximum output voltage 15 kV with possible load capacitance of: * 6 nF with a pulse width of 73 μs at a repetition rate of 2.5 kHz * 10 nF with a pulse width of 103 μs at a repetition rate of 1.25 kHz
· 1:1000 parallel voltage divider
· Overvoltage limitation at approx. 20–23 kV via parallel spark gaps
· Thermistor for overtemperature detection in 1st transformer stage
· Ground-side current measuring socket 100 mV/A
Breakdown Detection, Testing
· If the maximum bridge currents for transformer control or the max. currents of the full-bridge power supplies are exceeded, high voltage is switched off
· The device features a resettable operating hours counter to determine test duration
Manufacturer price approx. €59,500
Financing through our bank is also possible.
komplett-konzept.leasingo.de
More new and used items can be found in our shop!
International shipping costs on request!
Oglas je automatski preveden. Moguće su pogreške u prijevodu.
Dobavljač
Napomena: Registrirajte se besplatno ili prijavite, za pristup svim informacijama.
Zadnji put online: prošli tjedan
Registriran od: 2008
560 Oglasi online
Pošalji upit
Telefon & Faks
+49 2862 ... oglasi
Ovi oglasi bi vas također mogli zanimati.
Mali oglasi
Soerendonk
991 km
Mjenjač / Mjenjač
Flender / SiemensK2S-2,5
Flender / SiemensK2S-2,5
Mali oglasi
Wiefelstede
1.043 km
Stega za stol 150 mm
Heuer FrontSpannweite 235 mm
Heuer FrontSpannweite 235 mm
Vaš oglas je uspješno izbrisan
Došlo je do pogreške