Klimatski ormar 1300 litara s kontrolom vlageVötsch
VCS 7130-15 -70°C bis +180°C
Klimatski ormar 1300 litara s kontrolom vlage
Vötsch
VCS 7130-15 -70°C bis +180°C
Stanje
Rabljeno
Lokacija
Borken 

Pokaži slike
Prikaži kartu
Podaci o stroju
Cijena i lokacija
- Lokacija:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Nazovi
Detalji ponude
- ID broj oglasa:
- A19437121
- Referentni br.:
- 24666
- Zadnje ažurirano:
- dana 20.08.2025
Opis
Vötsch
Model: VCS 7130-15
Vötsch Climatic Test Chamber, Water-Cooled
Specifications for Temperature Testing:
Temperature range: -70°C to 180°C
Temporal temperature deviation at center of workspace: ±0.3 to ±0.8 K
Spatial temperature deviation: ±0.5 to ±2 K
Temperature gradient: 1 to 4 K
Temperature change rate:
Heating: 16 K/min
Cooling: 14.5 K/min
Specifications for Climatic Testing:
Temperature range: +10°C to +95°C
Humidity range: 10 to 98 % RH
Temporal temperature deviation at center of workspace: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1 K
Temperature gradient: 1 to 2 K
Humidity fluctuation over time at center of workspace: ±1 to ±3 % RH
Heat compensation: max. 8,000W
Housing Dimensions:
External dimensions (with hinges and door lock):
Height: 1,995 mm, Width: 1,680 mm, Depth: 1,855 mm
External dimensions (without hinges and door lock):
Height: 1,995 mm, Width: 1,300 mm, Depth: 1,855 mm
Internal dimensions: Height: 950 mm, Width: 1,100 mm, Depth: 950 mm
Test chamber volume: approx. 1,300 liters
Feedthroughs:
The test chamber is equipped with feedthroughs on the right and left sides. Measuring cables and test devices can be routed into the chamber through these feedthroughs.
1 x R1 NW 125 mm
1 x R1 NW 140 mm
1 x L1 NW 50 mm
Test Chamber Lighting:
Halogen bulb 24 V, 50 W
Electrical Connection:
3/N/PE AC 400V ±10% 50Hz
Nominal power: 44.0 kW
Nominal current: 63.0 A
Fused on site: 100 A slow-blow
Maximum heat emission to environment: 2.2 kW
Permissible Test Load:
Total load on shelves: 100 kg
Chamber floor: 150 kg, Insert shelf: 50 kg
Refrigerant for climate control: R 404A/R 23
Weight: 1,900 kg
For your safety as a buyer, please note the following:
The following procedures are performed on our offered chambers in advance:
1. Function check and replacement of necessary components
2. Refill with legally compliant refrigerant if required
3. Leak test with certificate
4. After successful inspection, chambers undergo a documented test run.
Condition: Used
Scope of delivery: (see pictures)
Knodpfx Aowvgwbsdped
(Specifications and details may be subject to change and errors!)
If you have further questions, feel free to contact us by phone.
Oglas je automatski preveden i možda je došlo do nekih grešaka u prijevodu.
Model: VCS 7130-15
Vötsch Climatic Test Chamber, Water-Cooled
Specifications for Temperature Testing:
Temperature range: -70°C to 180°C
Temporal temperature deviation at center of workspace: ±0.3 to ±0.8 K
Spatial temperature deviation: ±0.5 to ±2 K
Temperature gradient: 1 to 4 K
Temperature change rate:
Heating: 16 K/min
Cooling: 14.5 K/min
Specifications for Climatic Testing:
Temperature range: +10°C to +95°C
Humidity range: 10 to 98 % RH
Temporal temperature deviation at center of workspace: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1 K
Temperature gradient: 1 to 2 K
Humidity fluctuation over time at center of workspace: ±1 to ±3 % RH
Heat compensation: max. 8,000W
Housing Dimensions:
External dimensions (with hinges and door lock):
Height: 1,995 mm, Width: 1,680 mm, Depth: 1,855 mm
External dimensions (without hinges and door lock):
Height: 1,995 mm, Width: 1,300 mm, Depth: 1,855 mm
Internal dimensions: Height: 950 mm, Width: 1,100 mm, Depth: 950 mm
Test chamber volume: approx. 1,300 liters
Feedthroughs:
The test chamber is equipped with feedthroughs on the right and left sides. Measuring cables and test devices can be routed into the chamber through these feedthroughs.
1 x R1 NW 125 mm
1 x R1 NW 140 mm
1 x L1 NW 50 mm
Test Chamber Lighting:
Halogen bulb 24 V, 50 W
Electrical Connection:
3/N/PE AC 400V ±10% 50Hz
Nominal power: 44.0 kW
Nominal current: 63.0 A
Fused on site: 100 A slow-blow
Maximum heat emission to environment: 2.2 kW
Permissible Test Load:
Total load on shelves: 100 kg
Chamber floor: 150 kg, Insert shelf: 50 kg
Refrigerant for climate control: R 404A/R 23
Weight: 1,900 kg
For your safety as a buyer, please note the following:
The following procedures are performed on our offered chambers in advance:
1. Function check and replacement of necessary components
2. Refill with legally compliant refrigerant if required
3. Leak test with certificate
4. After successful inspection, chambers undergo a documented test run.
Condition: Used
Scope of delivery: (see pictures)
Knodpfx Aowvgwbsdped
(Specifications and details may be subject to change and errors!)
If you have further questions, feel free to contact us by phone.
Oglas je automatski preveden i možda je došlo do nekih grešaka u prijevodu.
Dobavljač
Napomena: Registrirajte se besplatno ili prijavite, za pristup svim informacijama.
Registran od: 2012
Predaj zahtjev
Telefon & Telefaks
+49 2861 ... oglasi
Vaš oglas je uspješno izbrisan
Došlo je do pogreške

















