Klimatska ispitna komora 990 litaraWeiss – 40…+ 180°C
WK11-1000/40 mit Zander K-MT 2
Klimatska ispitna komora 990 litara
Weiss – 40…+ 180°C
WK11-1000/40 mit Zander K-MT 2
Stanje
Rabljeno
Lokacija
Borken 

Pokaži slike
Prikaži kartu
Podaci o stroju
- Opis stroja:
- Klimatska ispitna komora 990 litara
- Proizvođač:
- Weiss – 40…+ 180°C
- Stanje:
- vrlo dobro (rabljeno)
Cijena i lokacija
- Lokacija:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Nazovi
Detalji ponude
- ID broj oglasa:
- A20761877
- Referentni br.:
- 24929
- Zadnje ažurirano:
- dana 12.01.2026
Opis
Weiss
Type: WK11-1000/40
Giodpfxsx Hxkzj Aa Asl
For sale is a professional climatic test chamber Weiss Umwelttechnik WT-WK 1000/40, equipped with a fully automatic cold-regenerating adsorption dryer.
The internals currently installed in the test chamber can be removed if required. At present, due to these installations, the control cabinet is limited to a temperature range from −40 °C to +60 °C. After removing the internal fixtures, the manufacturer can restore the standard temperature range of −40 °C to +180 °C, as the current fixtures are not suitable for high temperatures.
This unit is ideal for precise temperature and humidity testing of components, assemblies, and devices. Perfect for applications in industry, development, quality assurance, and research.
Weiss Climatic Test Chamber, Water-Cooled
Specifications for Temperature Testing:
- Temperature range: −40 °C to +60 °C
- Temporal temperature fluctuation (center of usable space): ±0.1 to ±0.5 K
- Spatial temperature deviation: ±0.5 to ±2.0 K
- Temperature change rate:
- Heating: 4 K/min
- Cooling: 3 K/min
Specifications for Climate Testing:
- Temperature range: +10 °C to +95 °C
- Humidity range: 10 to 98 % r.H.
- Temporal temperature fluctuation (center of usable space): ±0.1 to ±0.3 K
- Spatial temperature deviation: ±0.5 to ±1 K
- Temporal humidity fluctuation (center of usable space): ±1 to ±3 % r.H.
Heat compensation:
- In the range +25 °C to +95 °C
- At up to 90% relative humidity: 500 W
Humidification System Data:
- Reservoir volume: 20 l
- Water quality: demineralized
- pH value: 6 to 7
- Conductivity: 5 to 20 µS/cm³
- Water consumption at constant +40 °C, 92 % r.H.: 21 l/24 h
Temperature gradient (per IEC 60068-3-5): 1 to 2 K
Test chamber dimensions: Height: 950 mm, Width: 1100 mm, Depth: 950 mm
External dimensions: Height: 1980 mm, Width: 1385 mm, Depth: 1850 mm
Test volume: approx. 990 liters
Nominal voltage: 3/N/PE AC 400 V +10% 50 Hz
Nominal power: 11.5 kW, Nominal current: 22.0 A
Refrigerant: R 404A
Weight: 840 kg
Important safety information for buyers:
The following points are completed on all climate chambers offered:
1. Function check and replacement of necessary components
2. Refill with legally compliant refrigerant as needed
3. Leak test with certification
4. After successful inspection, a documented test run is performed.
Condition: used
Scope of delivery: (see pictures)
(Specifications and technical data subject to change and errors!)
For further questions, please contact us by phone.
Oglas je automatski preveden i možda je došlo do nekih grešaka u prijevodu.
Type: WK11-1000/40
Giodpfxsx Hxkzj Aa Asl
For sale is a professional climatic test chamber Weiss Umwelttechnik WT-WK 1000/40, equipped with a fully automatic cold-regenerating adsorption dryer.
The internals currently installed in the test chamber can be removed if required. At present, due to these installations, the control cabinet is limited to a temperature range from −40 °C to +60 °C. After removing the internal fixtures, the manufacturer can restore the standard temperature range of −40 °C to +180 °C, as the current fixtures are not suitable for high temperatures.
This unit is ideal for precise temperature and humidity testing of components, assemblies, and devices. Perfect for applications in industry, development, quality assurance, and research.
Weiss Climatic Test Chamber, Water-Cooled
Specifications for Temperature Testing:
- Temperature range: −40 °C to +60 °C
- Temporal temperature fluctuation (center of usable space): ±0.1 to ±0.5 K
- Spatial temperature deviation: ±0.5 to ±2.0 K
- Temperature change rate:
- Heating: 4 K/min
- Cooling: 3 K/min
Specifications for Climate Testing:
- Temperature range: +10 °C to +95 °C
- Humidity range: 10 to 98 % r.H.
- Temporal temperature fluctuation (center of usable space): ±0.1 to ±0.3 K
- Spatial temperature deviation: ±0.5 to ±1 K
- Temporal humidity fluctuation (center of usable space): ±1 to ±3 % r.H.
Heat compensation:
- In the range +25 °C to +95 °C
- At up to 90% relative humidity: 500 W
Humidification System Data:
- Reservoir volume: 20 l
- Water quality: demineralized
- pH value: 6 to 7
- Conductivity: 5 to 20 µS/cm³
- Water consumption at constant +40 °C, 92 % r.H.: 21 l/24 h
Temperature gradient (per IEC 60068-3-5): 1 to 2 K
Test chamber dimensions: Height: 950 mm, Width: 1100 mm, Depth: 950 mm
External dimensions: Height: 1980 mm, Width: 1385 mm, Depth: 1850 mm
Test volume: approx. 990 liters
Nominal voltage: 3/N/PE AC 400 V +10% 50 Hz
Nominal power: 11.5 kW, Nominal current: 22.0 A
Refrigerant: R 404A
Weight: 840 kg
Important safety information for buyers:
The following points are completed on all climate chambers offered:
1. Function check and replacement of necessary components
2. Refill with legally compliant refrigerant as needed
3. Leak test with certification
4. After successful inspection, a documented test run is performed.
Condition: used
Scope of delivery: (see pictures)
(Specifications and technical data subject to change and errors!)
For further questions, please contact us by phone.