Weiss
Model: WKL 100/40
Climate Test Chamber, Air-cooled
with Humidity Control -40 to +180°C
Key Specifications for Temperature Testing:
Temperature range: -40 to +180°C
Temperature differences under stabilized conditions:
Temporal temperature fluctuation at chamber center: ±0.3 to ±1 K
Spatial temperature deviation: ±0.5 to ±2 K
Temperature change rate:
Heating: 3.5 K/min
Cooling: 5 K/min
Heat compensation: max. 1100 W
Key Specifications for Climate Testing:
Humidification system data:
Reservoir capacity: approx. 13 l
Water quality: Deionized
pH value: 6 – 7
Conductivity: max. 20 μS/cm
Water consumption at constant temperature +40°C, 92% RH: 2 l / 24 h
Temperature range: +10 to +95°C
Humidity range: 10 to 98% RH
Temperature and humidity tolerances (stabilized conditions):
Temporal temperature fluctuation at chamber center: ±0.3 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±1.5 K
Temporal humidity fluctuation at chamber center: ±1 to ±3% RH
Specifications for Mechanical Load:
Maximum load on test chamber floor: 25 kg
Per shelf: 10 kg
Total load on shelf mounts: 50 kg
Cable port right: 50 mm Ø
Cable port left: 50 mm Ø
Interfaces: Ethernet (RJ45), USB
Operating Data:
Chamber lighting: Halogen bulb 24V, 50W
Rated voltage: 1/N / PE AC 230 V ±10% 50 Hz
Rated power: 3.0 kW
Rated current: 13.0 A
Fusing on site: 16A slow-blow
Protection class:
Control cabinet IP 22, control panel IP 54
Heat Emission (air-cooled chambers):
Max. heat emission to environment: 2000 W
Noise Measurement:
Sound pressure level (free-field measurement at 1 m distance, 1.6 m height):
approx. 56 dB(A)
Chamber volume: approx. 100 liters
Weight: 190 kg
Refrigerant: R-452a
Kedpfx Adoxxtuispjnd
For your safety as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. New filling with legally compliant refrigerant, if required
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See photo)
(Changes and errors in technical data reserved. All information subject to confirmation!)
Further questions can be answered by phone—feel free to contact us.
Oglas je automatski preveden i možda je došlo do nekih grešaka u prijevodu.
Model: WKL 100/40
Climate Test Chamber, Air-cooled
with Humidity Control -40 to +180°C
Key Specifications for Temperature Testing:
Temperature range: -40 to +180°C
Temperature differences under stabilized conditions:
Temporal temperature fluctuation at chamber center: ±0.3 to ±1 K
Spatial temperature deviation: ±0.5 to ±2 K
Temperature change rate:
Heating: 3.5 K/min
Cooling: 5 K/min
Heat compensation: max. 1100 W
Key Specifications for Climate Testing:
Humidification system data:
Reservoir capacity: approx. 13 l
Water quality: Deionized
pH value: 6 – 7
Conductivity: max. 20 μS/cm
Water consumption at constant temperature +40°C, 92% RH: 2 l / 24 h
Temperature range: +10 to +95°C
Humidity range: 10 to 98% RH
Temperature and humidity tolerances (stabilized conditions):
Temporal temperature fluctuation at chamber center: ±0.3 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±1.5 K
Temporal humidity fluctuation at chamber center: ±1 to ±3% RH
Specifications for Mechanical Load:
Maximum load on test chamber floor: 25 kg
Per shelf: 10 kg
Total load on shelf mounts: 50 kg
Cable port right: 50 mm Ø
Cable port left: 50 mm Ø
Interfaces: Ethernet (RJ45), USB
Operating Data:
Chamber lighting: Halogen bulb 24V, 50W
Rated voltage: 1/N / PE AC 230 V ±10% 50 Hz
Rated power: 3.0 kW
Rated current: 13.0 A
Fusing on site: 16A slow-blow
Protection class:
Control cabinet IP 22, control panel IP 54
Heat Emission (air-cooled chambers):
Max. heat emission to environment: 2000 W
Noise Measurement:
Sound pressure level (free-field measurement at 1 m distance, 1.6 m height):
approx. 56 dB(A)
Chamber volume: approx. 100 liters
Weight: 190 kg
Refrigerant: R-452a
Kedpfx Adoxxtuispjnd
For your safety as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. New filling with legally compliant refrigerant, if required
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See photo)
(Changes and errors in technical data reserved. All information subject to confirmation!)
Further questions can be answered by phone—feel free to contact us.