Opis
Weiss
Weiss Climate Test Chamber WKL 100/70
-70°C to +180°C Humidity 100 Liters
Compressor has been replaced!!
Air-cooled
For sale here is a professional climate test chamber from Weiss Umwelttechnik.
This unit is ideal for material testing, climatic tests, as well as temperature and humidity simulations in industry, laboratories, or development environments.
The test chamber enables precise test conditions across a wide range of extreme temperatures and high humidity levels.
Technical Data for Temperature Testing:
Temperature range: -70 to +180°C
Temperature deviation over time at chamber center: ± 0.3 to ± 1 K
Temperature uniformity (spatial), based on setpoint from tmin up to +150°C: ± 0.5 to ± 2 K
Rate of temperature change:
Heating: 3.5 K/min
Cooling: 3.5 K/min
Heat compensation: max. 700 W
Technical Data for Climate Testing:
Data for humidification system:
Reservoir volume: approx. 13 l
Water quality: demineralized
pH value: 6 – 7
Conductivity: max. 20 μS/cm
Water consumption at steady temperature +40°C, 92% r.h.: 2 l/24 h
Temperature range: +10 to +95°C
Humidity range: 10 to 98% r.h.
Temperature deviation over time at chamber center: ± 0.3 to ± 0.5 K
Temperature uniformity (spatial), based on setpoint: ± 0.5 to ± 1.5 K
Humidity deviation over time at chamber center: = 1 to ± 3% r.h.
Internal dimensions: Height 400 mm x Width 470 mm x Depth 345 mm
External dimensions: Height 1776 mm x Width 745 mm x Depth 980 mm
Mechanical Load Data:
Max. load of test chamber floor: 10 kg
Per shelf: 10 kg
Total load of shelf supports: 50 kg
Operational Data:
Test chamber lighting: Halogen bulb 24V, 50W
Rated voltage: 1/N / PE AC 230 V ± 10%, 50 Hz
Rated power: 3.5 kW
Rated current: 15.2 A
Line fuse: 16A slow-blow
Protection rating:
Control cabinet IP 22, control panel IP 54
Heat emission of air-cooled test chambers:
Max. heat output to ambient: 2500 W
Sound Measurement:
Sound pressure level, free-field measurement at 2m distance from front and 1.0m height: approx. 59 dB(A)
Feed-through: 50 mm ∅
Interfaces: Ethernet port (RJ45), USB port
Refrigerant: R404A / R23
Test chamber volume: approx. 100 liters
Weight: 210 kg
For your safety as a buyer, please note the following information!
The following work is carried out on our chambers prior to sale:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Specifications subject to change and errors reserved!)
For further questions you are welcome to contact us by phone.
Ljdjyw Nnfspfx Afxsri
Oglas je automatski preveden. Moguće su pogreške u prijevodu.
Weiss Climate Test Chamber WKL 100/70
-70°C to +180°C Humidity 100 Liters
Compressor has been replaced!!
Air-cooled
For sale here is a professional climate test chamber from Weiss Umwelttechnik.
This unit is ideal for material testing, climatic tests, as well as temperature and humidity simulations in industry, laboratories, or development environments.
The test chamber enables precise test conditions across a wide range of extreme temperatures and high humidity levels.
Technical Data for Temperature Testing:
Temperature range: -70 to +180°C
Temperature deviation over time at chamber center: ± 0.3 to ± 1 K
Temperature uniformity (spatial), based on setpoint from tmin up to +150°C: ± 0.5 to ± 2 K
Rate of temperature change:
Heating: 3.5 K/min
Cooling: 3.5 K/min
Heat compensation: max. 700 W
Technical Data for Climate Testing:
Data for humidification system:
Reservoir volume: approx. 13 l
Water quality: demineralized
pH value: 6 – 7
Conductivity: max. 20 μS/cm
Water consumption at steady temperature +40°C, 92% r.h.: 2 l/24 h
Temperature range: +10 to +95°C
Humidity range: 10 to 98% r.h.
Temperature deviation over time at chamber center: ± 0.3 to ± 0.5 K
Temperature uniformity (spatial), based on setpoint: ± 0.5 to ± 1.5 K
Humidity deviation over time at chamber center: = 1 to ± 3% r.h.
Internal dimensions: Height 400 mm x Width 470 mm x Depth 345 mm
External dimensions: Height 1776 mm x Width 745 mm x Depth 980 mm
Mechanical Load Data:
Max. load of test chamber floor: 10 kg
Per shelf: 10 kg
Total load of shelf supports: 50 kg
Operational Data:
Test chamber lighting: Halogen bulb 24V, 50W
Rated voltage: 1/N / PE AC 230 V ± 10%, 50 Hz
Rated power: 3.5 kW
Rated current: 15.2 A
Line fuse: 16A slow-blow
Protection rating:
Control cabinet IP 22, control panel IP 54
Heat emission of air-cooled test chambers:
Max. heat output to ambient: 2500 W
Sound Measurement:
Sound pressure level, free-field measurement at 2m distance from front and 1.0m height: approx. 59 dB(A)
Feed-through: 50 mm ∅
Interfaces: Ethernet port (RJ45), USB port
Refrigerant: R404A / R23
Test chamber volume: approx. 100 liters
Weight: 210 kg
For your safety as a buyer, please note the following information!
The following work is carried out on our chambers prior to sale:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Specifications subject to change and errors reserved!)
For further questions you are welcome to contact us by phone.
Ljdjyw Nnfspfx Afxsri
Oglas je automatski preveden. Moguće su pogreške u prijevodu.
Pošalji upit
Telefon & Faks
+49 2861 ... oglasi
Vaš oglas je uspješno izbrisan
Došlo je do pogreške