Opis
Weiss
Type: WKL 34/40
Weiss Climate Chamber, Air-Cooled
-40°C to 150°C
Chamber Volume: 34 liters
Standard built-in feedthroughs:
R1 NW 50 mm
L1 NW 120 mm
Internal dimensions: Height 310 mm, Width 324 mm, Depth 300 mm
External dimensions: Height 1740 mm, Width 630 mm, Depth 970 mm
Specifications for Temperature Testing:
Temperature range: -40 to +150 °C
Temperature differences at steady state (according to IEC 60068-3-5)
Temporal temperature fluctuation at the center of the usable space: ± 0.3 to ± 1 K, ± 1 to ± 2 K
Spatial temperature deviation (temperature gradient): 2 to 4
Temperature change rate (according to IEC 60068-3-5)
Heating: 2.5 K/min
Cooling: 3.5 K/min
Heat compensation max.: 800 W
Specifications for Climate Testing:
Temperature range: +10 to +95 °C
Humidity range: 10 to 98 % r.h.
Temperature and humidity deviations (steady state, according to IEC 60068-3-5)
Temporal temperature fluctuation at the center of the usable space: ± 0.3 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 K (temperature gradient): 1 to 3
Temporal humidity fluctuation at the center of the usable space: ± 3 to ± 5 % r.h.
Operating Data:
Test chamber lighting: Halogen bulb, 12V, 20W
Rated voltage: 1/N / PE AC 230V ± 10 % 50 Hz
Rated power: 1.8 kW
Rated current: 8.0 A
Customer-provided fuse: 16A slow-blow
Heat emission (air-cooled test chambers):
Max. heat emission to ambient: 800 W
Refrigerant: R-404A
Weight: 110 kg
Important note:
"The table shown in the photos is not included in the sale."
For your security as a buyer, the following steps are performed on all our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Recharge with legally compliant refrigerant if required
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see picture)
(Technical data, details, and specifications are subject to change and error!)
If you have further questions, please feel free to contact us by phone.
Gedpfx Aaexvpp Re Ajbg
Oglas je automatski preveden i možda je došlo do nekih grešaka u prijevodu.
Type: WKL 34/40
Weiss Climate Chamber, Air-Cooled
-40°C to 150°C
Chamber Volume: 34 liters
Standard built-in feedthroughs:
R1 NW 50 mm
L1 NW 120 mm
Internal dimensions: Height 310 mm, Width 324 mm, Depth 300 mm
External dimensions: Height 1740 mm, Width 630 mm, Depth 970 mm
Specifications for Temperature Testing:
Temperature range: -40 to +150 °C
Temperature differences at steady state (according to IEC 60068-3-5)
Temporal temperature fluctuation at the center of the usable space: ± 0.3 to ± 1 K, ± 1 to ± 2 K
Spatial temperature deviation (temperature gradient): 2 to 4
Temperature change rate (according to IEC 60068-3-5)
Heating: 2.5 K/min
Cooling: 3.5 K/min
Heat compensation max.: 800 W
Specifications for Climate Testing:
Temperature range: +10 to +95 °C
Humidity range: 10 to 98 % r.h.
Temperature and humidity deviations (steady state, according to IEC 60068-3-5)
Temporal temperature fluctuation at the center of the usable space: ± 0.3 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 K (temperature gradient): 1 to 3
Temporal humidity fluctuation at the center of the usable space: ± 3 to ± 5 % r.h.
Operating Data:
Test chamber lighting: Halogen bulb, 12V, 20W
Rated voltage: 1/N / PE AC 230V ± 10 % 50 Hz
Rated power: 1.8 kW
Rated current: 8.0 A
Customer-provided fuse: 16A slow-blow
Heat emission (air-cooled test chambers):
Max. heat emission to ambient: 800 W
Refrigerant: R-404A
Weight: 110 kg
Important note:
"The table shown in the photos is not included in the sale."
For your security as a buyer, the following steps are performed on all our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Recharge with legally compliant refrigerant if required
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see picture)
(Technical data, details, and specifications are subject to change and error!)
If you have further questions, please feel free to contact us by phone.
Gedpfx Aaexvpp Re Ajbg
Oglas je automatski preveden i možda je došlo do nekih grešaka u prijevodu.
Dobavljač
Napomena: Registrirajte se besplatno ili prijavite, za pristup svim informacijama.
Predaj zahtjev
Telefon & Telefaks
+49 2861 ... oglasi
Ovi oglasi bi vas također mogli zanimati.
Mali oglasi
Mögglingen
574 km
Stroj za mjerenje koordinata
KEYENCEWM 3000
KEYENCEWM 3000
Mali oglasi
Borken
970 km
Klimatska komora
VötschVC³ 4060
VötschVC³ 4060
Mali oglasi
Mainz
753 km
Skenirajući elektronski mikroskop (REM)
ZeissXB 350
ZeissXB 350
Mali oglasi
Borken
970 km
Ormar s izmjeničnom klimom
BinderMKF 720 E1 / E1.1
BinderMKF 720 E1 / E1.1
Mali oglasi
Borken
970 km
Klimatska komora
CTSC-40/200
CTSC-40/200
Mali oglasi
Borken
970 km
Visokokvalitetni uređaj za elementarnu analizu
BrukerS8 TIGER WDXRF Spektrometer
BrukerS8 TIGER WDXRF Spektrometer
Mali oglasi
Borken
970 km
Kabinet za temperaturu
WEISSWT3- 180/40
WEISSWT3- 180/40
Mali oglasi
Njemačka
731 km
Sustav filtera - sustav osmoze
Thermo Fisher ScientificECO 300
Thermo Fisher ScientificECO 300
Mali oglasi
Köln
893 km
čisti zrak radni stol
HeraguardHPH 15
HeraguardHPH 15
Mali oglasi
Borken
970 km
Klimatska ispitna komora sa šejkerom, 2160 litara
WeissWK3-2200/40/5/V -40°C bis +180°C
WeissWK3-2200/40/5/V -40°C bis +180°C
Vaš oglas je uspješno izbrisan
Došlo je do pogreške